Victaulic Catalog

AWWA Ductile Iron Pipe
Grooved System


Style 341
Vic-Flange Adapter


Note: Gray area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.

Nom.
Size
In./mm
Max.
Wk.
Pres.
PSI
kPa
Dimensions
Inches/mm
Aprx.
Wgt.
Ea.
Lbs.
kg
WZ
3
65
250
1725
8.44
214
0.94
24
5.4
2.4
4
100
250
1725
9.94
252
0.94
24
8.2
3.7
6
150
250
1725
12.00
305
1.00
25
12.0
5.4
8
200
250
1725
14.63
372
1.13
29
17.4
7.9
10
250
250
1725
17.19
437
1.19
30
24.6
11.2
12
300
250
1725
20.25
514
1.25
32
34.4
15.6
14
350
200
1375
-
-
1.50
38
55.0
25.0
16
400
150
1035
-
-
1.88
48
80.0
36.3
18
450
150
1035
-
-
2.25
57
95.0
43.1
20
500
150
1035
-
-
2.38
61
115.0
52.2
24
600
150
1035
-
-
2.50
64
150.0
68.0

Refer to notes, click here for details.
Style 341 requires sufficient clearance behind groove to permit proper assembly.

Style 341 Vic-Flange adapters provide direct connection of flanged components into a radius grooved cast pipe system of AWWA dimensions. Style 341 adapters utilize a special gasket (Grade "M" or "S") which seals on the pipe end and mating flange face.
Request 23.04.


Vic-Flange Adapter
Required Sealing Surface

SEALING SURFACE
Inches/millimeters
SEALING SURFACE
Inches/millimeters
Flange
Size
A
Maximum
B
Minimum
Flange
Size
A
Maximum
B
Minimum
3
65
3.96
101
4.94
125
14
350
15.30
389
16.38
416
4
100
4.80
122
5.88
149
16
400
17.40
442
18.38
467
6
150
6.90
175
8.00
203
18
450
19.50
495
20.00
508
8
200
9.05
230
10.13
257
20
500
21.60
549
22.50
572
10
250
11.10
292
12.50
318
24
600
25.80
655
27.75
705
12
300
13.20
335
14.75
375

* This area must be free from gouges, undulations or deformities of any type for effective sealing.
See Flange Adapter Notes,
click here for details.