Victaulic Catalog
AWWA Ductile Iron Pipe
Grooved System
Style 341
Vic-Flange Adapter
![]() | ![]() Note: Gray area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. |
| Nom. Size In./mm | Max. Wk. Pres. PSI kPa | Dimensions Inches/mm | Aprx. Wgt. Ea. Lbs. kg | |
| W | Z | |||
| 3 65 | 250 1725 | 8.44 214 | 0.94 24 | 5.4 2.4 |
| 4 100 | 250 1725 | 9.94 252 | 0.94 24 | 8.2 3.7 |
| 6 150 | 250 1725 | 12.00 305 | 1.00 25 | 12.0 5.4 |
| 8 200 | 250 1725 | 14.63 372 | 1.13 29 | 17.4 7.9 |
| 10 250 | 250 1725 | 17.19 437 | 1.19 30 | 24.6 11.2 |
| 12 300 | 250 1725 | 20.25 514 | 1.25 32 | 34.4 15.6 |
| 14 350 | 200 1375 | - - | 1.50 38 | 55.0 25.0 |
| 16 400 | 150 1035 | - - | 1.88 48 | 80.0 36.3 |
| 18 450 | 150 1035 | - - | 2.25 57 | 95.0 43.1 |
| 20 500 | 150 1035 | - - | 2.38 61 | 115.0 52.2 |
| 24 600 | 150 1035 | - - | 2.50 64 | 150.0 68.0 |
Refer to notes, click here for details.
Style 341 requires sufficient clearance behind groove to permit proper assembly.
Style 341 Vic-Flange adapters provide direct connection of flanged components into a radius grooved cast pipe
system of AWWA dimensions. Style 341 adapters utilize a special gasket (Grade "M" or "S") which seals on the
pipe end and mating flange face.
Request 23.04.
Vic-Flange Adapter
Required Sealing Surface
| SEALING SURFACE Inches/millimeters | SEALING SURFACE Inches/millimeters | ||||
| Flange Size | A Maximum | B Minimum | Flange Size | A Maximum | B Minimum |
| 3 65 | 3.96 101 | 4.94 125 | 14 350 | 15.30 389 | 16.38 416 |
| 4 100 | 4.80 122 | 5.88 149 | 16 400 | 17.40 442 | 18.38 467 |
| 6 150 | 6.90 175 | 8.00 203 | 18 450 | 19.50 495 | 20.00 508 |
| 8 200 | 9.05 230 | 10.13 257 | 20 500 | 21.60 549 | 22.50 572 |
| 10 250 | 11.10 292 | 12.50 318 | 24 600 | 25.80 655 | 27.75 705 |
| 12 300 | 13.20 335 | 14.75 375 | |||
* This area must be free from gouges, undulations or deformities of any type for effective sealing.
See Flange Adapter Notes, click here for details.