Victaulic Catalog
Design Data
Design Data
The "Nominal Pipe Size - Inches" column in charts shows the corresponding ISO Nominal Size-Millimeters; "Pipe OD -Inches," shows the equivalent ISO Pipe OD in millimeters. All other dimensions are direct metric (International System of Units-SI) conversions of the U.S. figures as an aid for those requiring metric data. Conversions are based on the following formulas as listed in ANSI Z210.1 American National Standard - Metric Practice.
Conversion Chart
| Convert U.S. to Metric | ||
| 25.4 x Inches (In.) | = | Millimeters (mm) x 0.03937 |
| 0.3048 x Feet (Ft.) | = | Meters (m) x 3.281 |
| 0.4536 x Pounds (Lbs.) | = | Kilograms (kg) x 2.205 |
| 28.35 x Ounces (Oz.) | = | Grams (g) x 0.03527 |
| 6.894 x Pressure (PSI) | = | Kilopascals (kPa) x 0.145 |
| .069 x Pressure | = | Bar x 14.5 |
| 4.45 x End Load (Lbs.) | = | Newtons (N) x 0.2248 |
| 1.356 x Torque (Lb. Ft.) | = | Newtons Meters (Nm) x 0.738 |
| F-32 / 1.8 Temp. (°F) | = | Celcius (°C) C + 17.78 x 1.8 |
| 745.7 x Horsepower (hp) | = | Watts (W) x 1.341 x 10-3 |
| 3.785 x Gal per Min. (GPM) | = | Liters per Min. (L/M) x 0.2642 |
| 3.7865 x 10-3 Gal. per Min. (GPM) | = | Cubic Meters Per Min. (m3/-m) x 264.2 |
This Victaulic General Catalog has been written for the piping system installer, designer, specification writer and owner as a basic reference for data about Victaulic mechanical piping methods. This catalog is organized to provide information in the context and form most readily usable. It is fully indexed in the front for easy identification of major sections and subsections of interest. Victaulic has developed, in nearly 70 years in mechanical piping, variations ofpiping practice for use on a wide variety of piping materials. This catalog is organized to explain the major data necessary for proper assembly and installation.
NOTICE
The technical and performance data, weights, dimensions and specifications published in this catalog supersede
all previously published data. Victaulic Company of America maintains a continual policy of product
improvement and, therefore, reserves the right to change product specifications, designs, and standard
equipment without notice and without incurring obligation. The material presented in this catalog is intended for
piping design reference in utilization of Victaulic products for their intended application. It is not intended as a
substitute for competent, professional assistance which is an obvious requisite to any specific application.
INSTALLATION
Reference should always be made to Victaulic Field Assembly and Installation Pocket-Handbook (I-100-latest
edition) included with each shipment of Victaulic products, for complete installation and assembly data.
DESIGN
Reference should always be made to design information available at no charge on request from Victaulic. Good
piping practices should always prevail. Specific presssures, temperatures, external or internal loads, performance
standards and tolerances must never be exceeded. Many applications require recognition of special conditions,
code requirements and use of safety factors. Qualified engineers must make these decisions. While every effort
has been made to ensure its accuracy Victaulic Company of America, its subsidiaries and affiliated companies,
make no express or implied warranty of any kind respecting the information contained in this catalog or the
material referred to herein. Anyone making use of the information or material contained herein does so at his own
risk and assumes any and all liability resulting from such use.
IMPORTANT INFORMATION
Victaulic grooved pipe couplings are designed for use only with pipe grooved to meet Victaulic groove
specifications and Victaulic grooved end fittings, valves, and related grooved end components only. They are
not intended for use with plain end pipe and/or fittings.
Victaulic plain end couplings are designed for use only with plain end or beveled end steel pipe (unless
otherwise indicated) and Victaulic plain end fittings. Victaulic plain end couplings must not be used with
grooved end or threaded pipe and/or fittings. Pipe must be prepared to meet Victaulic specifications outlined for
each specific product style. Proper performance data listed herein is based on proper pipe preparation. The
proper gasket must be selected for the service intended. It should be noted that there are various services for
which Victaulic gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket
Selection Guide for specific gasket service recommendations and for a listing of services which are not
recommended.
Gaskets for Victaulic products always must be lubricated for proper assembly. Gasket lubricant must meet
manufacturer's specifications. Thorough lubrication of the gasket exterior, including the lips and/or pipe ends
and housing interiors, is essential to prevent gasket pinching. Lubrication assists proper gasket seating and
alignment during installation. Victaulic has a complete line of tools for preparing pipe to Victaulic specifications.
Use of these tools is recommended in preparing pipe to receive Victaulic products. Always read and understand
the Tool Operating Instructions supplied with every Victaulic tool prior to using any tools.
All data contained herein, is subject to change without notice.
All rights reserved. Printed in the United States of America No part of this Victaulic catalog may be reproduced,stored in a
retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise,
without the prior written permission of Victaulic Company of America.
©Copyright 1995, Victaulic Company of America ®Registered trademark of Victaulic Company of America