Victaulic Catalog

IPS Stainless Steel Pipe
Pressfit System


Style 574
Concentric Reducer

(T x I)
F- _ _ _ - 574 - X - 2 - T

Nominal
Size
Inches/mm
Dimensions - Inches/mmWeight
Each
Lbs./kg
E - EMinimum
L1L2
1 x 3/4
25 x 20
3.56
90
1.03
26
1.00
25
0.24
0.1
1 1/4 x 1
32 x 25
3.69
94
1.25
32
1.03
26
0.34
0.2
1 1/2 x 3/4
40 x 20
4.06
103
1.44
37
1.00
25
0.36
0.2
x 1
x 25
4.06
103
1.44
37
1.03
26
0.39
0.2
x 1 1/4
x 32
4.25
108
1.44
37
1.25
32
0.43
0.2
2 x 3/4
50 x 20
4.88
124
1.81
46
1.00
25
0.61
0.3
x 1
x 25
4.88
124
1.81
46
1.03
26
0.61
0.3
x 1 1/2
x 40
4.88
124
1.81
46
1.44
37
0.68
0.3

Style 576
Male Adapter

(P x M)
F - _ _ _ - 576 - X - _ - M

Nominal
Size
Inches/mm
Dimensions
Inches/mm
Wgt.
Each
Lbs.
kg
Nominal
Size
Inches/mm
Dimensions
Inches/mm
Wgt.
Each
Lbs.
kg
E - ETakeout
U
E - ETakeout
U
3/4 x 1/2
20 x 15
3.22
82
1.74
44
0.26
0.1
1 1/4 x 1 1/4
32 x 32
4.18
106
2.17
55
0.52
0.2
x 3/4
x 20
3.72
94
2.23
56
0.31
0.1
1 1/2 x 3/4
40 x 20
3.69
94
2.20
56
0.60
0.3
x 1
x 25
3.22
62
1.47
37
0.39
0.2
x 1 1/2
x 40
4.40
112
2.14
54
0.66
0.3
1 x 3/4
25 x 20
3.34
85
1.77
45
0.35
0.1
2 x 2
50 x 50
5.03
128
2.35
60
1.00
0.5
x 1
x 25
4.02
102
2.19
55
0.40
0.2

* Length of effective thread.


Pipe Support
(Stainless Steel)

Nom.
Pipe
Size
In./mm
Sugg. Max. Span Between
Supports - Feet/meters
Nom.
Pipe
Size
In./mm
Sugg. Max. Span Between
Supports - Feet/meters
Water ServiceGas/Air ServiceWater ServiceGas/Air Services
B31.1B31.9B31.1B31.9B31.1B31.9B31.1B31.9
3/4
20
7
2.1
8
2.4
9
2.7
8
2.4
1 1/2
40
7
2.1
12
3.7
9
2.7
13
4.0
1
25
7
2.1
9
2.7
9
2.7
9
2.7
2
50
10
3.1
13
4.0
13
4.0
15
4.6
1 1/4
32
7
2.1
11
3.4
9
2.7
11
3.4

Piping joined with Pressfit System products, like all other piping systems, requires support to carry the weight of pipes and equipment. As for other methods of joining pipes, the support or hanging method must be such as to eliminate undue stresses on joints, piping and other components. Additionally, the method of support must be such as to allow movement of the pipes where required and to provide drainage, etc., as may be specified by the designer.
The Maximum Hanger Spacing corresponds to ANSI B31.1 or B31.9 as noted and should be used only in conjunction with Victaulic Pressfit System products on Approved Schedule 5 stainless steel pipe.