Victaulic Catalog
IPS Carbon Steel Pipe
Grooved Couplings
Rigid Coupling Performance
| Nom. Size In./mm | Allow. Pipe End Sep. In./mm | Nom. Size In./mm | Allow. Pipe End Sep. In./mm |
| 3/4 20 | 0.05 1.2 | 5 1/2 § | 0.16 4.1 |
| 1 25 | 0.05 1.2 | 6 150 | 0.16 4.1 |
| 1 1/4 32 | 0.05 1.2 | 6 1/4 § | 0.16 4.1 |
| 1 1/2 40 | 0.05 1.2 | 6 1/2 § | 0.16 4.1 |
| 2 50 | 0.07 1.7 | 8 200 | 0.19 4.8 |
| 2 1/2 65 | 0.07 1.7 | 10 250 | 0.13 3.3 |
| 3 § | 0.07 1.7 | 12 300 | 0.13 3.3 |
| 3 80 | 0.07 1.7 | 14 350 | 0.13 3.3 |
| 4 100 | 0.16 4.1 | 16 400 | 0.13 3.3 |
| 4 1/4 § | 0.16 4.1 | 18 450 | 0.13 3.3 |
| 5 125 | 0.16 4.1 | 20 500 | 0.13 3.3 |
| 5 1/4 § | 0.16 4.1 | 24 600 | 0.09 2.3 |
§ O.D. Dimension
Zero-Flex Style 07, FireLock Style 005 and Transition Style 307 Rigid Couplings have a unique, patented angle pad design which constricts the housing keys into the groove around the full circumference to grip the pipe rigidly. The housings slide on the angled pads rather than mating squarely.
This sliding adjustment also forces the key sections into opposed contact on the inside and the outside groove edges, pushing the joint to its maximum pipe end separation (see chart below) during assembly.
These rigid couplings provide a rigid joint allowing no expansion! contraction or linear movement. Couplings will push the pipe ends to their maximum allowable separation which must he considered during assembly.
Rigid couplings (Styles 07, 005, 008, 307, HP-70, 741 and others) create a rigid joint, useful for risers, mechanical rooms and other areas where flexibility is not desired. Zero-Flex Style 97 and FireLock Style 005 couplings are designed to provide rigidity to permit hanging to ANSI B31.1 Power Piping Code, ANSI B31 .9 Building Services Piping Code and NFPA 13 Sprinkler Systems.
Flexible Coupling Performance
| Nom. Size Inches mm | Allow Pipe End Sep. §§ Inch./mm | Deflect. Fr. CL §§ | Nom. Size Inches mm | Allow Pipe End Sep. §§ Inch./mm | Deflect. Fr. CL §§ | ||
| Degrees per Cplg. | Pipe In./ft. mm/m | Degrees per Cplg. | Pipe In./ft. mm/m | ||||
| 3/4 20 | 0 - 0.06 0 - 1.6 | 3° - 24' | 0.72 60 | 6 150 | 0 - 0.13 0 - 3.2 | 1° - 5' | 0.23 18 |
| 1 25 | 0 - 0.06 0 - 1.6 | 2° - 43' | 0.57 48 | 6 1/4 §§ | 0 - 0.13 0 - 3.2 | 1° - 9' | 0.24 20 |
| 1 1/4 32 | 0 - 0.06 0 - 1.6 | 2° - 10' | 0.45 38 | 6 1/2 §§ | 0 - 0.13 0 - 3.2 | 1° - 6' | 0.23 19 |
| 1 1/2 40 | 0 - 0.06 0 - 1.6 | 1° - 56' | 0.40 33 | 8 §§ | 0 - 0.13 0 - 3.2 | 0° - 54' | 0.16 13 |
| 2 50 | 0 - 0.06 0 - 1.6 | 1° - 31' | 0.32 26 | 8 200 | 0 - 0.13 0 - 3.2 | 0° - 50' | 0.18 14 |
| 2 1/2 65 | 0 - 0.06 0 - 1.6 | 1° - 15' | 0.26 22 | 10 §§ | 0 - 0.13 0 - 3.2 | 0° - 43' | 0.15 11 |
| 3 § | 0 - 0.06 0 - 1.6 | 1° - 12' | 0.26 22 | 10 250 | 0 - 0.13 0 - 3.2 | 0° - 40' | 0.14 12 |
| 3 80 | 0 - 0.06 0 - 1.6 | 1° - 2' | 0.22 18 | 12 §§ | 0 - 0.13 0 - 3.2 | 0° - 36' | 0.13 9 |
| 3 1/2 90 | 0 - 0.06 0 - 1.6 | 0° - 54' | 0.19 16 | 12 300 | 0 - 0.13 0 - 3.2 | 0° - 34' | 0.12 9 |
| 4 100 | 0 - 0.13 0 - 3.2 | 1° - 36' | 0.34 28 | 14 350 | 0 - 0.13 0 - 3.2 | 0° - 31' | 0.11 9 |
| 4 1/4 § | 0 - 0.13 0 - 3.2 | 1° - 41' | 0.35 29 | 15 375 | 0 - 0.13 0 - 3.2 | 0° - 29' | 0.10 9 |
| 4 1/2 120 | 0 - 0.13 0 - 3.2 | 1° - 26' | 0.25 21 | 16 400 | 0 - 0.13 0 - 3.2 | 0° - 27' | 0.10 9 |
| 5 125 | 0 - 0.13 0 - 3.2 | 1° - 18' | 0.27 23 | 18 450 | 0 - 0.13 0 - 3.2 | 0° - 24' | 0.08 7 |
| 5 1/4 § | 0 - 0.13 0 - 3.2 | 1° - 21' | 0.28 24 | 20 500 | 0 - 0.13 0 - 3.2 | 0° - 22' | 0.08 7 |
| 5 1/2 § | 0 - 0.13 0 - 3.2 | 1° - 18' | 0.28 24 | 22 550 | 0 - 0.13 0 - 3.2 | 0° - 19' | 0.07 6 |
| 6 § | 0 - 0.13 0 - 3.2 | 1° - 12' | 0.21 18 | 24 600 | 0 - 0.13 0 - 3.2 | 0° - 18' | 0.07 6 |
§§ NOTE: These values are based on standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. See Notes below.
§ O.D. Dimension
Standard grooved-type couplings allow controlled angular, linear and rotational movement at each joint to accommodate expansion, contraction, settling, vibration, noise and other piping system movement. These features provide advantages in designing piping systems but must he considered when determining hanger and support spacing and location.
Victaulic couplings offer superior vibration attenuation characteristics to both flexible metal and elastomeric flexible arch-type connectors.
Independent vibration testing data (request 26.04) verifies that three Victaulic couplings in close proximity to a vibration source (pump, equipment, etc.) provide superior vibration attenuation in piping systems.
Both type couplings otter installed cost savings from 10 to 30% and higher, plus the convenience of a union at every joint and the proven. pressure-responsive "C" shaped Victaulic gasket. Both type products fit into standard roll or cut grooved pipe and provide the security of all circumferential engagement of the coupling housing into the groove for high pressure and end load service.
General Notes for Dimensional Tables * Working Pressure and End Load are total, from all internal and external loads, based on standard weight
(ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for
performance on other pipe. All products shall be installed in accordance with current Victaulic installation/assembly instructions. |