Victaulic Catalog
IPS Carbon Steel Pipe
Hole Cut Products
Style 923
Vic-Let Strapless
Outlet
![]() | ![]() | ![]() |
| Nom. Size Inches/mm | Dimensions Inches/mm | Aprx. Wgt. Ea. Lbs. | |
| Run x Br. | Hole Saw Size | Vic-let T ** | |
| 4 - 8 x 1/2 100 - 200 x 15 | 1.50 38.1 | 2.47 63 | 1.9 0.9 |
| x 3/4 x 20 | 1.50 38.1 | 2.44 62 | 1.6 0.7 |
| > 10 x 1/2 > 250 x 15 | 1.50 38.1 | 2.47 63 | 1.9 0.9 |
| x 3/4 x 20 | 1.50 38.1 | 2.44 62 | 1.6 0.7 |
** Inside wall of run to engaged pipe end.
FLOW DATA: Flow area equivalent to 3/4" (20 mm) pipe. Accepts 7/16" (11 mm) probe.
WARNING: Always depressurize system and drain before disassembly.
DUE TO DEFORMATION OF THE COLLAR, VIC-LET SHOULD NOT BE RE-USED AFTER INITIAL
INSTALLATION.
The Victaulic Style 923 Vic-Let outlet has integral lugs which insert into a hole cut in the pipe, gripping against
the pipe's inside wall, while a nut threaded on the main body is tightened.
Style 923 Vic-Let are rated at 300 psi (2065 kPa) working pressure for standard weight steel pipe.
Request 11.05.
Style 924
Vic-O-Well Strapless
Thermometer Outlet
![]() | ![]() | ![]() |
| Nom. Size Inches/mm | Dimensions Inches/mm | Aprx. Wgt. Ea. Lbs. kg | |
| Hole Saw Size | Vic-O-Well T ** | ||
| 4 - 8 § 100 - 200 | 1.50 38.1 | 3.00 76 | 2.4 1.1 |
| > 10 § > 250 | 1.50 38.1 | 3.00 76 | 2.3 1.0 |
§ For 6" (500 mm) stem.
** Inside wall of run to end of probe.
WARNING: Always depressurize system and drain before disassembly.
DUE TO DEFORMATION OF THE COLLAR, VIC-O-WELL THERMOMETER WELL SHOULD NOT BE
RE-USED AFTER INITIAL INSTALLATION.
The Victaulic Style 924 Vic-O-Well outlet main body casting has integral lugs which insert into a hole, gripping
against the I.D. wall, while a nut threaded on the main body. The Vic-O-Well outlet main body is machined
internally to standard thread well dimensions. Both sizes are rated at 300 PSI (2065 kPa) working pressure on
steel pipe.
Request 11.06.