Victaulic Catalog

IPS Carbon Steel Pipe
Grooved End Accessories


Style 734 & 734S
Orifice/Indicator
Flow Metering Sensor

Nom.
Size
Inches/mm
End to End
A
Inches/mm
Aprx.
Wgt. Ea.
Lbs./kg
2 1/2
65
3.50
89
2.0
0.9
3
80
3.50
89
2.6
1.2
4
100
3.63
92
3.9
1.8
5
125
4.25
108
5.7
2.6
6
150
4.25
108
7.2
3.3
8
200
4.75
121
11.9
5.4
10
250
5.00
127
17.8
8.1
12
300
5.00
127
21.2
9.6
14
350
5.38
137
22.0
10.0
16
400
5.38
137
30.5
13.8
18
450
5.50
140
35.0
15.9
20
500
6.19
157
45.5
20.6
24
600
7.19
183
62.7
28.4

Victaulic Style 734/734S Orifice/ Indicator flow metering system (orifice type) provides an accurate and economical way to obtain flow measurements
For proper installation, 2 1/2" to 4" (65 - 100 mm) sizes have a minimum straight pipe requirement of 5 diameters upstream and two downstream; for 5" (125 mm) and up, 10 diameters upstream and four downstream. Standard rating for Style 734 is 250 PSI (1725 kPa) at 230°F (+110°C) water.
Request 09.09.


Style 734 & 734S §
Orifice/Indicator
Performance

Size
Inches
mm
Flow
Co-Efficient
C
Size
Inches
mm
Flow
Co-Efficient
C
Size
Inches
mm
Flow
Co-Efficient
C
2 1/2L
65
12
45
4L
100
25
95
12
300
406
1537
2 1/2H
65
19
72
4M
100
35
132
14
450
490
1855
3H
80
29
110
5
125
64
242
16
400
640
2422
3L
80
16
61
6
150
89
337
18
450
810
3066
3M
80
22
83
8
200
177
670
20
500
1000
3785
4H
100
52
198
10
250
269
1018
24
600
1500
5678

§ For Styles 733, 734 & 734S, C (Flow Co-efficient) is Q (Flow in GPM) for P (Pressure Drop) of 1* H20.
Formula to determine Q (GPM), given C:
Q(GPM) = C x

Values for flow of water at +60°F (+16°C) for 1 inch of water (0.25 kPa) pressure drop in Gallons per Minute (Liters per Minute).